Single Phase Electric Motor

What Motor Should You Use for Household Appliances, Small Pumps and Fans? A Complete Guide to Single-Phase Motors

View single-phase electric motor specifications and request a quote

Single-phase motors are common in compact equipment where three-phase power is not available. The right choice depends on starting torque, running duty, capacitor arrangement, speed, voltage and the available mounting space—not just the nameplate power.

Tell us the duty point, nameplate data and installation requirements. We can confirm the practical variant before you place an order.

A single-phase motor is an asynchronous motor powered by a single-phase AC power supply. Since it only requires single-phase AC, it is convenient to use and widely applied. It has the advantages of simple structure, low cost, low noise, and minimal interference with radio systems. The frame numbers range from H56 to H132, with power typically ranging from 0.06kW to 3.7kW, and the number of poles includes 2 and 4 poles. Single-phase asynchronous motors consist of a main winding and an auxiliary winding. Depending on the starting method and capacitor configuration, they are mainly divided into the YY series capacitor-run, YC series capacitor-start, YL series dual-capacitor, and YU series split-phase start. Among them, the YY series has a high power factor, smooth operation, and relatively low starting torque; the YC series has high starting torque, reaching more than 2.5 times the rated torque; the YL series is equipped with both starting and running capacitors, with a large capacitor during starting and a small capacitor during operation, providing high starting torque and good operational performance, making it the best in single-phase asynchronous motors; the YU series has the simplest structure but low starting torque. Why choose a single-phase motor? First, it can operate on a single-phase power supply without requiring a three-phase power supply, making it suitable for homes, small workshops, and rural areas without three-phase electricity. Second, it has a simple structure and low cost. Compared with three-phase motors, single-phase motors have simpler structures and lower manufacturing and maintenance costs. Third, it produces low noise and minimal interference, suitable for household appliances and noise-sensitive environments. Fourth, it has a wide range of applications; household appliances and small power machinery with lower power requirements can use it, such as electric fans, washing machines, refrigerators, air conditioners, range hoods, electric drills, medical equipment, small fans, and household water pumps. Fifth, it is lightweight and flexible to install, with aluminum housing series being 40%–50% lighter than cast-iron motors, suitable for scenarios requiring weight reduction. Single-phase motors are mainly used in: household appliances such as fans, washing machines, refrigerators, air conditioner compressors, range hoods, hair dryers, and exhaust fans; small industrial equipment such as miniature water pumps, pulping machines, threshers, grinders, woodworking machines, and medical equipment; commercial equipment such as HVAC systems, refrigeration equipment, pumps, compressors, and ventilation systems; and agricultural equipment such as irrigation pumps, grain processing equipment, and small conveyors. Who needs single-phase motors? Household appliance manufacturers for OEM supply, small water pump and fan manufacturers, medical equipment and food machinery manufacturers, industrial motor distributors and stockists, equipment maintenance and replacement procurement teams, export traders, targeting markets with small- and medium-power motor demand in the Middle East, Southeast Asia, South America, etc. In what situations should single-phase motors be selected or replaced? When the equipment uses a single-phase 220V power supply and cannot connect to three-phase power; small equipment OEM supply requiring compact motors; upgrading or replacing old motors; household appliance repair or replacement; exporting to single-phase voltage markets, such as 120V in the US, 100V in Japan, 230V in Europe; EU market requires single-phase motors to meet IE2 energy efficiency levels. How to choose a single-phase motor? Step one: determine power, calculate based on load shaft power, with a 15%–25% safety margin; step two: choose the series, high starting torque select YC or YL series, low starting torque and smooth operation select YY series; step three: choose the number of poles, 2-pole about 2800 rpm, 4-pole about 1400 rpm; step four: choose frame size H56–H132; step five: choose installation method B3 foot-mounted horizontal, B5 large flange vertical, B14 small flange vertical, B34 foot + small flange, B35 foot + large flange; step six: confirm voltage and frequency, 220V/50Hz standard, can be customized to 110V, 115V, 230V, 60Hz; step seven: confirm protection and insulation, IP44 standard, IP54/IP55 optional, class B insulation standard, class F/H optional; step eight: confirm duty S1 continuous duty, ambient temperature -15°C to +40°C, altitude ≤1000m.

Model example: `YC90S-2`, meaning YC series, frame 90, S core length, 2 poles.

YY series single-phase capacitor-run motor (2-pole, 50Hz, 220V, example)

Model Power W Current A Efficiency % Power factor Speed r/min Capacitor uF/V
YY6312 180 1.37 65 0.92 2800 8uF/400V
YY6322 250 1.87 66 0.92 2800 12uF/400V
YY7112 370 2.77 64 0.95 2800 15uF/450V
YY7122 550 3.87 68 0.95 2800 20uF/450V
YY8012 750 4.88 71 0.95 2800 25uF/400V
YY8022 1100 7.67 74 0.95 2800 30uF/400V
YY90S2 1500 10.5 74 0.95 2800 40uF/400V
YY90L2 2200 13.5 74 0.95 2800 45uF/400V

YC series single-phase capacitor-start motor (2-pole/4-pole, 50Hz, 220V, example)

Model Power kW Current A Speed r/min Efficiency % Power factor Locked Rotor Torque / Rated Locked Rotor Current / Rated
YC90S-2 0.75 5.94 2800 70 0.82 2.5 6.5
YC90S-4 0.55 5.57 1400 65 0.69 2.5 6.5
YC90L-4 0.75 6.87 1400 69 0.73 2.5 6.5
YC90L-2 1.1 8.74 2800 72 0.82 2.5 6.5

YL Series Single-phase Dual-capacitor Motor (2-pole/4-pole, 50Hz, 220V, Example)

Model Power kW Current A Speed r/min Efficiency % Power factor Locked Rotor Torque / Rated Locked Rotor Current / Rated
YL90S-2 1.5 9.5 2800 76 0.94 1.7 6.0
YL90S-4 1.1 7.21 1400 75 0.93 1.7 6.0
YL90U-2 2.2 13.67 2800 77 0.95 1.7 6.0
YL90L-4 1.5 9.57 1400 75 0.95 1.7 6.0

General Technical Parameter Table

Parameter Specification
Type Single-phase Asynchronous Motor
Power Range 0.06–3.7kW
Frame Range H56–H132
Number of Poles 2P / 4P
Rated Voltage Standard 220V; customizable 110V/115V/230V
Rated Frequency Standard 50Hz; customizable 60Hz
Energy Efficiency Level Meets IE2 (EU) 2019/1781 requirements, power ≥0.12kW
Protection Level Standard IP44; optional IP54/IP55
Insulation Class Standard Class B; optional Class F/H
Cooling Method IC0141 Totally Enclosed Fan-Cooled (TEFC)
Duty S1 Continuous Duty
Ambient Temperature -15°C to +40°C
Altitude ≤1000m
Relative Humidity ≤90%(25°C)
Housing Material Aluminum Alloy / Cast Iron Optional
Bearing High-quality Ball Bearing
Capacitor Starting capacitor / running capacitor, configured by series

Supporting pump application reference (example)

Motor power Number of Poles Supporting pump type Reference flow Reference head Typical application
0.06–0.25kW 2P/4P Micro pumps, circulation pumps 0.5–3 m³/h 3–15m Small water circulation, cooling systems
0.37–0.75kW 2P/4P Small centrifugal pumps, self-priming pumps 2–10 m³/h 10–30m Water supply, irrigation, cleaning
1.1–2.2kW 2P/4P Centrifugal pumps, pipeline pumps 5–25 m³/h 15–50m Water treatment, boosting, circulation
3.0–3.7kW 2P/4P Multistage pumps, medium-sized pumps 15–80 m³/h 30–100m Industrial water supply, process pumps

The above are examples; actual applications must be calculated based on pump curves, medium density, and pipeline loss.

Dimension drawing placeholder: `[Image: /images/single-phase-motor-dimension-drawing-b3.webp]`

Key dimension table (B3 installation, example)

Frame A mm B mm C mm D shaft diameter mm E shaft length mm F key width mm H center height mm K hole diameter mm Weight kg
56 90 71 36 φ9 20 3 56 5.8 2.5
63 100 80 40 φ11 23 4 63 7 3.5
71 112 90 45 φ14 30 5 71 7 4.5
80 125 100 50 φ19 40 6 80 10 5.5
90S 140 100 56 φ24 50 8 90 10 6.5
90L 140 125 56 φ24 50 8 90 10 7.5

Material table

Component Standard material Optional material Description
Housing, end cover Aluminum alloy die-casting Cast iron Aluminum housing is lightweight, cast iron has good rigidity
Stator winding Copper wire 100% copper wire Class B standard, F/H class optional
Rotor Cast aluminum squirrel cage — Reliable, low maintenance
Shaft 45# carbon steel Stainless steel Quenching and tempering treatment
Bearing High-quality Ball Bearing NSK/SKF —
Fan cover Steel plate — IC0141 cooling
Junction box Aluminum alloy / plastic Top or right side —
Capacitor Start capacitor / Run capacitor Dual-value capacitor Configured by series

Installation method

Installation code Description IM code Typical application
B3 Motor base with feet, end cover without flange IMB3 Horizontal pumps, fans, compressors
B5 Motor base without feet, end cover with large flange IMB5 Vertical pumps, pipeline pumps
B14 Motor base without feet, end cover with small flange IMB14 Small pumps, compact equipment
B34 Motor base with feet, end cover with small flange IMB34 Can be used horizontally or vertically
B35 Motor base with feet, end cover with large flange IMB35 Heavy-duty horizontal or vertical use

Installation check points: foundation flat, foot bolt holes aligned; use shims to level for B3 installation, tighten foot bolts diagonally; B5/B14 flange surface clean, no burrs; align motor shaft with equipment shaft, radial and angular error suggested ≤0.05mm; confirm rotation direction with jog before power-on; correct capacitor wiring, start capacitor connected via centrifugal switch.

Application scenario table

Industry Application Recommended series Key requirements
Household Appliances Electric fans, washing machines, refrigerators, air conditioners YY/YC Low noise, IP44
Water Pumps Small centrifugal pumps, self-priming pumps, pipeline pumps YL/YC High starting torque
Fans Axial fans, centrifugal fans, exhaust fans YY Smooth operation
Compressors Small piston air compressors YC/YL High starting torque
Medical Equipment Small pumps, fans, drives YY Low noise, compact
Food Machinery Blenders, meat grinders, dough kneaders YC IP54, easy to clean
Agricultural Machinery Irrigation pumps, grain processing YL Durable, cost-effective
Refrigeration Equipment Condenser fans, chiller units YY Long-term continuous operation

Note: Please choose explosion-proof motors for explosive environments; single-phase motors are not suitable.

## Technical FAQ

1. What is a single-phase motor?

A single-phase motor is an asynchronous motor powered by a single-phase AC power supply, usually with small capacity, easy to use, and widely applied in industrial, agricultural, and household appliances.

2. What is the power range of a single-phase motor?

Standard 0.06kW–3.7kW, frame H56–H132.

3. What is the difference between the YY, YC, and YL series?

YY is running capacitor type, with low starting torque but smooth operation; YC is starting capacitor type, with high starting torque; YL is dual-value capacitor type, combining high starting torque and excellent operating performance.

4. What is the energy efficiency level of a single-phase motor?

EU Regulation (EU) 2019/1781 requires single-phase motors with power ≥0.12kW to meet IE2 energy efficiency level.

5. What is the protection level of single-phase motors?

Standard IP44, optional IP54, IP55.

6. What is the insulation class of single-phase motors?

Standard class B insulation, optional class F and class H.

7. What installation methods are supported by single-phase motors?

B3、B5、B14、B34、B35。

8. What is the voltage and frequency of single-phase motors?

Standard 220V/50Hz, customizable 110V, 115V, 230V, 60Hz. Foreign single-phase voltages include the US 120V, Japan 100V, Germany/UK/France 230V.

9. Can single-phase motors be used with a frequency converter?

Generally not recommended. Single-phase motors are usually not suitable for variable frequency drive; if speed control is required, it is recommended to use a three-phase motor with a variable frequency drive.

10. What is the ambient temperature range for single-phase motors?

-15°C to +40°C, altitude ≤1000m, humidity ≤90%.

11. What is the cooling method of single-phase motors?

IC0141 fully enclosed self-ventilated.

12. What are the bearings of single-phase motors?

High-quality ball bearings.

13. What is the duty type of single-phase motors?

S1 continuous duty.

14. How to select a single-phase motor for a water pump?

Calculate the pump shaft power, reserve 15%–25% margin, select pole number based on speed, confirm the starting torque requirement—use YC or YL series for high starting torque.

15. Can single-phase motors be customized?

Voltage, frequency, installation method, shaft extension, F/H-class insulation, IP55, special paint, thermal protector, capacitor configuration, etc. can be customized.

16. What is the difference between single-phase and three-phase motors?

Single-phase motors only require a single-phase power supply, have smaller power, and are suitable for household and small equipment; three-phase motors require a three-phase power supply, have a wide power range, high efficiency, and are suitable for industrial and mining applications.

17. Can single-phase motors be used in explosive environments?

No. Explosive environments must use explosion-proof motors such as YBX3.

Technical FAQ

When should I use a single-phase motor instead of a three-phase motor?

Use a single-phase motor when the site supply is single phase and the load is compatible. For larger or heavily loaded equipment, a three-phase motor is usually the better engineering option.

How do I choose the capacitor version?

Match the required starting torque and the manufacturer’s wiring diagram. Do not substitute capacitor values without checking current, temperature and start performance.

Authoritative references

For standards and energy guidance, see IEC standards and the U.S. Department of Energy motor systems guidance. Use the references as a starting point and confirm the exact edition required for your market.

Back to blog